DENTAL IMPLANTS ANALYSIS WITH SEM MICROSCOPE

UDC: 616.314-089.843:77.026.34

Авторы

  • Ljupka Arsovski Faculty of Medical Sciences, University Goce Delcev, Stip, North Macedonia
  • Sofija Carčeva Salja Faculty of Medical Sciences, University Goce Delcev, Stip, North Macedonia
  • Verica Toneva Stojmenova Faculty of Medical Sciences, University Goce Delcev, Stip, North Macedonia
  • Sonja Rogoleva Gjurovski Faculty of Medical Sciences, University Goce Delcev, Stip, North Macedonia
  • Marko Mladenovski Faculty of Medical Sciences, University Goce Delcev, Stip, North Macedonia
  • Sanja Nashkova Faculty of Medical Sciences, University Goce Delcev, Stip, North Macedonia

Ключевые слова:

chemical, contamination, detector, implants, sterile.

Аннотация

scanning electron microscope (SEM) is a type of electron microscope that produces images of a sample by scanning its surface with a focused beam of electrons. The electrons interact with the atoms in the sample, generating various signals that contain information about the surface topography and composition of the sample. The electron beam is scanned in a raster pattern, and the beam position is combined with the intensity of the detected signal to create an image. In the most common SEM mode, secondary electrons emitted by atoms excited by the electron beam are detected using a secondary electron detector (Everhart-Thornley detector). The number of secondary electrons that can be detected, and thus the signal intensity, depends, among other factors, on the sample's topography. Some SEMs can achieve resolutions better than 1 nanometer. Samples are observed under high vacuum in a conventional SEM or under low vacuum or wet conditions in a variable pressure or environmental SEM. They can also be examined across a wide range of cryogenic or elevated temperatures using specialized instruments. The instrument model is Tescan Vega 3 LMU. In dentistry, samples must first be prepared using an appropriate method depending on what will be analyzed. After that, they need to be further prepared for microscopy. In this case, the sample was applied only to a holder with a double-sided adhesive carbon tape without coating. The analyses were performed under high vacuum using an SE detector for morphological examination and an EDS detector for point chemical analysis. For handling the implants, sterile gloves were used to prevent additional contamination.

Скачивания

Данные по скачиваниям пока не доступны.

Библиографические ссылки

[1] Dhaliwal JS, David SRN, Zulhilmi NR, Dhaliwal SKS, Knights J, de Albuquerque Junior RF.

Contamination of titanium dental implants: a narrative review. SN Appl Sci. 2020;2:1–10.

[2] Makary C, Menhall A, Lahoud P, An HW, Park KB, Traini T. Nanostructured Calcium-Incorporated

Surface Compared to Machined and SLA Dental Implants—A Split-Mouth Randomized Case/Double-

Control Histological Human Study. Nanomaterials. 2023;13(2):357.

[3] Meng HW, Chien EY, Chien HH. Dental implant bioactive surface modifications and their effects on

osseointegration: a review. Biomark Res. 2016;4:1–14.

[4] Mtanis T, Biadsee A, Ormianer Z. Assessing the cleanliness of dental implants using scanning electron

microscopy and energy-dispersive X-ray spectroscopy analysis—a SEM and EDS in vitro study. J Funct

Biomater. 2023;14(3):172. doi:10.3390/jfb14030172

[5] Torta F, Hoffmann N, Burla B, Alecu I, Arita M, Bamba T, et al. Concordant inter-laboratory derived

concentrations of ceramides in human plasma reference materials via authentic standards. Nat Commun.

2024;15(1):8562. doi:10.1038/s41467-024-52087-x

[6] Kitagawa M, Murakami S, Akashi Y, Oka H, Shintani T, Ogawa I, et al. Current status of dental metal

allergy in Japan. J Prosthodont Res. 2018:1–4. doi:10.1016/j.jpor.2019.01.003

[7] Deng C, Shen X, Yang W, Luo Z, Ma P, Shen T, et al. Construction of zinc-incorporated nano-network

structures on a biomedical titanium surface to enhance bioactivity. Appl Surf Sci. 2018;453:263–70.

doi:10.1016/j.apsusc.2018.05.097

[8] Bahraminasab M, Bozorg M, Ghaffari S, Kavakebian F. Electrochemical corrosion of Ti-Al₂O₃

biocomposites in Ringer’s solution. J Alloys Compd. 2019;777:34–43. doi:10.1016/j.jallcom.2018.09.313

[9] Lukaszewska-Kuska M, Wirstlein P, Majchrowski R, Dorocka-Bobkowska B. Osteoblastic cell

behaviour on modified titanium surfaces. Micron. 2018;105:55–63. doi:10.1016/j.micron.2017.11.010

[10] Jiang J, Han G, Zheng X, Chen G, Zhu P. Characterization and biocompatibility study of hydroxyapatite

coating on the surface of titanium alloy. Surf Coat Technol. 2019;375:645–51.

doi:10.1016/j.surfcoat.2019.07.067

Опубликован

2025-10-27

Как цитировать

DENTAL IMPLANTS ANALYSIS WITH SEM MICROSCOPE: UDC: 616.314-089.843:77.026.34. (2025). ETIMA, 3(1), 226-230. https://js.ugd.edu.mk/index.php/etima/article/view/7507